BQTJB - INPRO-CLEAN 2500
- MSDS: BQTJB
- Manufacturer: OAKITE PRODUCTS INC
- Product Name: INPRO-CLEAN 2500
- National Stock Number: 7930-00N036560
Product Identification
Product ID:INPRO-CLEAN 2500
MSDS Date:12/21/1988
FSC:7930
NIIN:00N036560
MSDS Number: BQTJB
Responsible Party
BERKELEY HEIGHTS, NJ 07922
US
Emergency Phone: 201-462-6900;800-424-9300(CHEMTREC)
Info Phone: 201-462-6900
Cage: 44389
Contractor
Telephone: 908-464-6900
Cage: 44389
Ingredients
PYROPHOSPHORIC ACID, TETRASODIUM SALT; (TETRASODIUM
CAS: 7722-88-5
RTECS: UX7350000
Fraction By Weight: <10%
OSHA PEL 5 MG/M3
ACGIH TLV: 5 MG/M3
1)
CAS: 497-19-8
RTECS: VZ4050000
Fraction By Weight: 20-30%
1)
CAS: 7757-82-6
RTECS: WE1650000
Fraction By Weight: <10%
SODIUM TETRABORATE PENTAHYDRATE
CAS: 1303-43-4
Fraction By Weight: 10-20%
SODIUM SALT CONDENSED NAPHTHALENESULFONIC ACID
CAS: 9084-06-4
Fraction By Weight: <5%
ETHANOL, 2- (2-BUTOXYETHOXY)-; (DIETHYLENE GLYCOL MONOBUTYL
CAS: 112-34-5
RTECS: KJ9100000
Fraction By Weight: <5%
GLYCOLS, POLYETHYLENE, MONO (NONYLPHENYL) ETHER;
CAS: 9016-45-9
RTECS: MD0900000
Fraction By Weight: <5%
GLYCOLS, POLYETHYLENE, MONO ((1,1,3,3-TETRAMETHYLBUTYL)
CAS: 9036-19-5
RTECS: MD0907600
Fraction By Weight: <5%
NON-HAZARDOUS INGREDIENTS
Fraction By Weight: BALANCE
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION OF DUST MAY CAUSE
IRRITATION OF MUCOUS MEMBRANES. DIRECT CONTACT CAUSES IRRITATION OF
EYES.PROLONGED SKIN CONTACT MAY CAUSE IRRITATION. ALTHOUGH
ABSORPTION THROUGH INTACT SKIN IS UNLIKELY, CONTACT WITH BURNED OR
ABRADED SKIN MAYRESULT IN SYSTEMIC POISONING AND WEAKNESS. SEVERE
CASES MAY BE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: CHARACTERIZED BY SHOCK, RAPID
HEARTBEAT, AND CYANOSIS.
Medical Cond Aggravated by Exposure:NONE KNOWN.
First Aid
First Aid:EYES: IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR AT LEAST 15
MINUTES. GET MEDICAL ATTENTION IF IRRITATION PERSISTS. SKIN: WASH
AFFECTED AREA WITH LARGE AMOUNTS OF WATER. GET MEDICAL ATTENTION IF
IRRIT ATION PERSISTS. INHALATION: MOVE VICTIMTO FRESH AIR. GET
MEDICAL ATTENTION. INGESTION: CONTACT LOCAL POISON CONTROL CENTER
OR PHYSICIAN IMMEDIATELY.
Fire Fighting
Flash Point:NONE
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING MATERIAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.
Accidental Release
Spill Release Procedures:WEAR PERSONAL PROTECTIVE EQUIPMENT. CAREFULLY
CLEAN UP SPILLED MATERIAL AND PLACE IN DRY CONTAINER FOR DISPOSAL.
AVOID DUST GENERATION. FLUSH AREA WITH PLENTY OF WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:IF TLV IS EXCEEDED OR FOR SYMPTOMS OF
OVEREXPOSURE WEAR NIOSH/MSHA APPROVED RESPIRATOR FOR DUST/MIST.
Ventilation:LOC EXHST MAY BE NEC FOR SOME HNDLG/USE CNDTNS. SPECIFIC
NEEDS SHOULD BE ADDRESSED BY SUPERVISORY OR HLTH/SAFETY PERS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WEAR NEOPRENE OR OTHER CHEMICAL RESISTANT
CLOTHING AS NEEDED TO PREVENT PROLONGED OR REPEATED SKIN CONTACT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
PH: 9.4 @ 40 G/L.
Chemical Properties
HCC:N1
Spec Gravity:8.4 (H*2O=1)
pH:SUPDAT
Solubility in Water:APPRECIABLE
Appearance and Odor:OFF-WHITE POWDER; MILD ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE KNOWN.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.